12:25:26 sean-k-mooney Dmitrii-Sh: i think the simpelst thing to do is as follows. 0 do not modify placment for this specifically. 1 add the extra identifiesr to the pci_device extra info column, 2. add that info the the prot profile. 3 modify the ml2 drivers to sotre the coallation beween the ovn chassi name and the device and have it use that value instead
12:25:26 sean-k-mooney Dmitrii-Sh: i think the simpelst thing to do is as follows. 0 do not modify placment for this specifically. 1 add the extra identifiesr to the pci_device extra info column, 2. add that info the the prot profile. 3 modify the ml2 drivers to sotre the coallation beween the ovn chassi name and the device and have it use that value instead
12:25:51 gibi Dmitrii-Sh: thanks, I get it
12:25:51 gibi Dmitrii-Sh: thanks, I get it
12:26:25 sean-k-mooney gibi: yep you can do it with connectx-6 cards i think intel were working on it at one point too but no idea if its still a thing they are planning on
12:26:25 sean-k-mooney gibi: yep you can do it with connectx-6 cards i think intel were working on it at one point too but no idea if its still a thing they are planning on
12:26:50 sean-k-mooney gibi: one of the things i was investigating in the past was could we move nova-compute to the smart nic too
12:26:50 sean-k-mooney gibi: one of the things i was investigating in the past was could we move nova-compute to the smart nic too
12:27:16 gibi this is crazy talk :D
12:27:16 gibi this is crazy talk :D
12:27:32 gibi sorry, my brain failed
12:27:32 gibi sorry, my brain failed
12:27:53 sean-k-mooney idea bing you would jsut grab a stanarcd server and install libvirt on it then you would just install an OpenstackPowerd smarntic that rann all the openstack servics in the server and its an instance compute node after some config updates
12:27:53 sean-k-mooney idea bing you would jsut grab a stanarcd server and install libvirt on it then you would just install an OpenstackPowerd smarntic that rann all the openstack servics in the server and its an instance compute node after some config updates
12:28:24 sean-k-mooney gibi: in this case they are jsut trying to move the networkign contol plane to the smarnic and not all the contol plane
12:28:24 sean-k-mooney gibi: in this case they are jsut trying to move the networkign contol plane to the smarnic and not all the contol plane
12:28:34 gibi ... and then at some point that smartnic is connected to two hypervisors and we are back to the one compute host multiple compute node situation :)
12:28:34 gibi ... and then at some point that smartnic is connected to two hypervisors and we are back to the one compute host multiple compute node situation :)
12:28:37 sean-k-mooney same basic idea however just run less stuff on the hypervior host
12:28:37 sean-k-mooney same basic idea however just run less stuff on the hypervior host
12:29:09 sean-k-mooney gibi: hehe lol lets hope this and rack scale design never have a baby
12:29:09 sean-k-mooney gibi: hehe lol lets hope this and rack scale design never have a baby
12:30:03 sean-k-mooney Dmitrii-Sh: by the way os-vif can connect to ovs over tcp to do the pluggin fo the interface into the ovs bridge
12:30:03 sean-k-mooney Dmitrii-Sh: by the way os-vif can connect to ovs over tcp to do the pluggin fo the interface into the ovs bridge
12:30:04 Dmitrii-Sh sean-k-mooney: I see. (1) ok, there will be some more info stored per pci_device but that's not too bad (2) ok, this can be done during the port update (3) yes, Neutron would need to look up a hostname of a chassis based on the serial number.
12:30:04 Dmitrii-Sh sean-k-mooney: I see. (1) ok, there will be some more info stored per pci_device but that's not too bad (2) ok, this can be done during the port update (3) yes, Neutron would need to look up a hostname of a chassis based on the serial number.
12:30:27 Dmitrii-Sh sean-k-mooney: I think os-vif can only use one OVS endpoint
12:30:27 Dmitrii-Sh sean-k-mooney: I think os-vif can only use one OVS endpoint
12:30:28 sean-k-mooney Dmitrii-Sh: so we can have os-vif running in the compute agent talk to ovs on the smart nic if it has an ip
12:30:28 sean-k-mooney Dmitrii-Sh: so we can have os-vif running in the compute agent talk to ovs on the smart nic if it has an ip
12:30:36 Dmitrii-Sh sean-k-mooney: comes back to the dual-NIC case
12:30:36 Dmitrii-Sh sean-k-mooney: comes back to the dual-NIC case
12:31:06 sean-k-mooney Dmitrii-Sh: corrrect today. but you could tell use what endpoitn to connecto to in the binding:detail from the ml2 driver
12:31:06 sean-k-mooney Dmitrii-Sh: corrrect today. but you could tell use what endpoitn to connecto to in the binding:detail from the ml2 driver
12:31:13 sean-k-mooney if we need that
12:31:13 sean-k-mooney if we need that
12:31:32 sean-k-mooney e.g. make the config value the defualt and allow it to change per port if needed
12:31:32 sean-k-mooney e.g. make the config value the defualt and allow it to change per port if needed
12:32:28 sean-k-mooney Dmitrii-Sh: yep so if we take this approch we can still track pci device in placment as a seperat effort without having to take account of the network backend in use
12:32:28 sean-k-mooney Dmitrii-Sh: yep so if we take this approch we can still track pci device in placment as a seperat effort without having to take account of the network backend in use
12:32:54 gibi hm does this whole thing also suggest that a single neutron-ovs-agent will handle more than on OVS instance (one per smartnic)?
12:32:54 gibi hm does this whole thing also suggest that a single neutron-ovs-agent will handle more than on OVS instance (one per smartnic)?
12:33:19 gibi s/on OVS/one OVS/
12:33:19 gibi s/on OVS/one OVS/
12:33:30 sean-k-mooney no but we might have multipel ovs agents on the same physical server one running on each smart nic
12:33:30 sean-k-mooney no but we might have multipel ovs agents on the same physical server one running on each smart nic
12:33:52 gibi wait, not just the OVS runs on the smartnic but also the neutron agent?
12:33:52 gibi wait, not just the OVS runs on the smartnic but also the neutron agent?
12:33:56 sean-k-mooney gibi: unless we revisit the scaleable ovs agent spec whic intended to od that
12:33:56 sean-k-mooney gibi: unless we revisit the scaleable ovs agent spec whic intended to od that
12:34:28 sean-k-mooney gibi: well in teh case of ovn theere would be a seperate ovn contoler per smartnic form what i understand
12:34:28 sean-k-mooney gibi: well in teh case of ovn theere would be a seperate ovn contoler per smartnic form what i understand
12:34:49 sean-k-mooney so if we are talking about ml2/ovs i would assume we would have 1 agent per smartnic Dmitrii-Sh is that correct?
12:34:49 sean-k-mooney so if we are talking about ml2/ovs i would assume we would have 1 agent per smartnic Dmitrii-Sh is that correct?
12:35:10 Dmitrii-Sh sean-k-mooney: ok, I'll have a look at whether something falls over with that approach. One challenge is NIC resource allocation when multiple compute nodes are involved but let's see.
12:35:10 Dmitrii-Sh sean-k-mooney: ok, I'll have a look at whether something falls over with that approach. One challenge is NIC resource allocation when multiple compute nodes are involved but let's see.
12:35:12 sean-k-mooney gibi: the neturon l2 agent and ovn southd are basically equvlent
12:35:12 sean-k-mooney gibi: the neturon l2 agent and ovn southd are basically equvlent
12:35:15 Dmitrii-Sh sean-k-mooney: yes, 1 per nic
12:35:15 Dmitrii-Sh sean-k-mooney: yes, 1 per nic
12:35:40 Dmitrii-Sh sean-k-mooney: I considered having something crazy that had 1 ARM host but 2 NICs
12:35:40 Dmitrii-Sh sean-k-mooney: I considered having something crazy that had 1 ARM host but 2 NICs
12:35:43 sean-k-mooney Dmitrii-Sh: can we declare multi host nics out of scope of the inital proposal
12:35:43 sean-k-mooney Dmitrii-Sh: can we declare multi host nics out of scope of the inital proposal
12:35:45 Dmitrii-Sh but I haven't seen hw like that
12:35:45 Dmitrii-Sh but I haven't seen hw like that
12:36:11 sean-k-mooney its not crazy i have seen hardware that was designed to work that way
12:36:11 sean-k-mooney its not crazy i have seen hardware that was designed to work that way
12:36:29 sean-k-mooney it was a top of rack swtich that had a pcie card that plugged into your servers
12:36:29 sean-k-mooney it was a top of rack swtich that had a pcie card that plugged into your servers
12:36:51 sean-k-mooney each server tought it was getting a nic but actully it all the nic hardware was on the switch
12:36:51 sean-k-mooney each server tought it was getting a nic but actully it all the nic hardware was on the switch
12:37:37 Dmitrii-Sh I guess that would be similar to 1 SmartNIC with PCIe bifurcation? Some lanes go to one CPU, some to another?
12:37:37 Dmitrii-Sh I guess that would be similar to 1 SmartNIC with PCIe bifurcation? Some lanes go to one CPU, some to another?
12:37:54 sean-k-mooney kind of yes
12:37:54 sean-k-mooney kind of yes
12:38:08 Dmitrii-Sh so, in this case, there would be 2 PFs exposed to the hypervisor host under different root complexes
12:38:08 Dmitrii-Sh so, in this case, there would be 2 PFs exposed to the hypervisor host under different root complexes
12:38:28 Dmitrii-Sh and the NUMA node association of PFs (and their VFs) would be based on that too
12:38:28 Dmitrii-Sh and the NUMA node association of PFs (and their VFs) would be based on that too
12:38:33 sean-k-mooney basically it was a ginant pcie switch on one end that connectd to multiple hosts and then a ether net switch on the other
12:38:33 sean-k-mooney basically it was a ginant pcie switch on one end that connectd to multiple hosts and then a ether net switch on the other
12:39:11 sean-k-mooney Dmitrii-Sh: ya you can do the pci biforcation with mellonox connetx5 today
12:39:11 sean-k-mooney Dmitrii-Sh: ya you can do the pci biforcation with mellonox connetx5 today
12:39:40 sean-k-mooney they have a 200G sku that has 2x 16 connectors that can connect to 2 different cpus
12:39:40 sean-k-mooney they have a 200G sku that has 2x 16 connectors that can connect to 2 different cpus
12:39:55 sean-k-mooney it get 2 PFs and the VF can float between them
12:39:55 sean-k-mooney it get 2 PFs and the VF can float between them
12:40:26 Dmitrii-Sh sean-k-mooney: yes, there's a special connector on the NIC and an add-in card that plugs to a different topology
12:40:26 Dmitrii-Sh sean-k-mooney: yes, there's a special connector on the NIC and an add-in card that plugs to a different topology
12:40:40 Dmitrii-Sh and the NIC is smart enough to use 2 sets of lanes differently
12:40:40 Dmitrii-Sh and the NIC is smart enough to use 2 sets of lanes differently
12:40:53 sean-k-mooney yep hardware vendors make software enginers look sane
12:40:53 sean-k-mooney yep hardware vendors make software enginers look sane
12:41:06 Dmitrii-Sh sean-k-mooney: :^D
12:41:06 Dmitrii-Sh sean-k-mooney: :^D
12:41:29 gibi lol
12:42:00 Dmitrii-Sh sean-k-mooney: ok, I am aiming to make the design extensible such that those things can be supported but I will avoid focusing on it for the initial proposal then