14:39:05 sean-k-mooney dmitriis: im trying to avoid failure in nova when thing like that ar changed
14:39:54 dmitriis sean-k-mooney: yeah, probably worth one VM failing to boot than the whole daemon dying because of the exception
14:39:56 dmitriis totally agree
14:40:50 sean-k-mooney yep plus as i said in the neutron ml2 driver you can fail the port binding an log an explit error message if the required info is not present
14:41:18 dmitriis sean-k-mooney: also very true
14:41:25 sean-k-mooney you could proably also add a check in nova at a differnt point if you wanted before that but i woudl just log the error form neutron personlaly
14:42:18 dmitriis sean-k-mooney: I'll log a warning in Nova in this case and simply return no data in the profile and let Neutron fail to bind
14:42:38 sean-k-mooney well you shoudl not return an empty profile
14:42:52 sean-k-mooney this code will be used for other VFs that may not be remote managed
14:43:04 sean-k-mooney and tehy do not need the vf number
14:43:11 sean-k-mooney we pass the vf pci adress
14:43:20 sean-k-mooney that is all they need in the general case
14:43:38 dmitriis rephrasing: 1. if PF MAC cannot be retrieved, do not include vf_num or card_serial_number either
14:43:56 dmitriis 2. if vf_num cannot be retrieved, do not include pf_mac and card_serial_number
14:44:24 sean-k-mooney ah well ya perhaps
14:44:39 sean-k-mooney i was thinking just include all the info you can always but i guess that works too
14:45:35 dmitriis ok, just need to fix the tests a little and I'll re-upload
14:45:45 sean-k-mooney ack
14:46:57 sean-k-mooney dmitriis: by the way have you tested this feature with a second ovs on the compute host
14:47:27 sean-k-mooney we had some internal question regarding can we have both offpath port and on path port on the same host
14:48:09 sean-k-mooney the reason for that was to use vm management port with vnic_type=normal and datapalne prots with vnic_type=smartnic
14:48:20 dmitriis sean-k-mooney: i.e. having a DPU and a regular SR-IOV card
14:48:37 sean-k-mooney well dpu and another nic that can be used with ovs or linux bridge
14:48:41 dmitriis right
14:49:03 dmitriis I haven't tested that explicitly but just trying to think what would that entail
14:49:07 sean-k-mooney basically it was raised that by using the dpu you are limiting the numer or port that can be created to the number of vfs
14:49:22 sean-k-mooney dmitriis: i think it should just work honestly
14:49:32 sean-k-mooney i was just wondering if you had considerd it
14:49:50 dmitriis sean-k-mooney: yes, the limitation on the number of ports have definitely come up in our conversations
14:50:11 sean-k-mooney dmitriis: all it really requires is the ml2 dirver changes to not require you to designate a host as only dpu enabled
14:50:18 dmitriis and nothing immediately jumps into mind regarding OVS on the host being a problem
14:50:23 sean-k-mooney e.g. make the binding desiion per port based on vnic_type
14:50:54 sean-k-mooney ack that is what my assement was too
14:51:04 dmitriis sean-k-mooney: yeah and IIRC it's just based on the vnic_type, we just added handling for vnic_type smartnic to the OVN mechanism driver
14:51:14 dmitriis so it should just bind a normal port regularly
14:51:20 sean-k-mooney yep
14:51:23 sean-k-mooney cool
14:51:44 sean-k-mooney we are still trying to assess what woudl be requried to eventually support this in our product
14:52:04 dmitriis sean-k-mooney: yeah, plus hardware is hard to come by
14:52:12 sean-k-mooney that too
14:52:45 dmitriis I think this feature will be useful for FPGA-based SmartNICs as well. I've seen the ones with a separate CPU but with an FPGA instead of an ASIC
14:53:24 dmitriis considering the DPDK dataplane usage at the SmartNIC's CPU side for that with rte_flow for offload
14:53:26 sean-k-mooney i do potentially have access to a BF2 that i coudl use but only 1 so i obviouly cant test multi node and in general an all in one deployment while useful is not fully reflective of how it would be deployed in a datacenter
14:53:34 dmitriis the Nova and Neutron bits would work the same though
14:53:46 sean-k-mooney dmitriis: yes in princial it could be
14:53:54 dmitriis sean-k-mooney: I have an idea on how to test multi-node with just one BF2
14:54:15 sean-k-mooney the only fpga based smartnic i have use used armstong os with only 2 arm cores and i think 4GB of ram
14:54:44 sean-k-mooney dmitriis: run two copies of nova-compute with difernt host values in teh conf on the same host
14:54:53 dmitriis sean-k-mooney: 2 VMs with nested virt a the hypervisor, plus 2 VMs at the DPU side. Each VM uses 1 PF. VPD can be faked by bind mounting a file in the right sysfs location
14:54:53 sean-k-mooney and use differnt ports on the BF2?
14:55:08 dmitriis BF2's ARM CPU is virt-capable btw xD
14:55:43 sean-k-mooney dmitriis: that proably wotn work becaue wehn the PF is passed to the qemu instacle the pcie capablityies are not in the pci config space in teh guest
14:56:10 sean-k-mooney lspci in the guest will only print the pci capablities not the extened pcie cabalities like sriov
14:56:15 sean-k-mooney in my previous experince
14:56:20 sean-k-mooney even when using q35
14:56:28 dmitriis sean-k-mooney: I was about to ask about q35 :^)
14:56:30 sean-k-mooney if it does work let me know :)
14:56:37 dmitriis sean-k-mooney: there's another option
14:56:49 dmitriis BF2 on one host + ConnectX on another
14:57:16 dmitriis just use the remote_managed feature with ovs/ovn-controller running locally on the connectx node
14:57:47 sean-k-mooney ya i tought about that
14:58:00 sean-k-mooney jsut addign the serial to the chasis table for the hosts ovn
14:58:09 dmitriis yes
14:58:15 sean-k-mooney in prinicapal that would owrk without BF2
14:58:43 dmitriis yes, technically, we just made Nova and Neutron realize that networking agents may run remotely but the trivial case is running locally
14:58:47 sean-k-mooney i did not really want to say that to our qe however :)
14:59:00 dmitriis yeah, fair enough :^)
14:59:25 sean-k-mooney but ya in principal we can test most of the integration that way for any nic that supprot vpd
15:00:01 dmitriis or even bind mount a file to the right sysfs location
15:00:03 sean-k-mooney i.e. if we can get the serial,mac and vf number we can test the end to end integration
15:00:20 dmitriis I got used to crafting VPD blobs since I needed to unit test the libvirt change
15:00:33 dmitriis basically, I crafted them byte-by-byte
15:00:51 dmitriis sean-k-mooney: ^ yes
15:01:02 sean-k-mooney ya thats doable
15:01:20 sean-k-mooney although i dont think it woudl be hard to have a python class that modeled it and just serialise it as a byte string
15:01:35 sean-k-mooney rather then do it by hand
15:01:47 sean-k-mooney unfortunetly i dont think we can use that to test in the upstream ci
15:02:03 dmitriis sean-k-mooney: yeah, it's not too hard. The only tricky part there is checksum calculation but it's a simple algorithm
15:02:24 sean-k-mooney crc32 or similar i assume
15:02:42 sean-k-mooney it would not be hard to look at the c code and ectra
15:02:47 dmitriis sean-k-mooney: just one's complement
15:02:56 sean-k-mooney that said im not sure libvirt cares about the crc
15:03:11 sean-k-mooney ack
15:03:30 dmitriis sean-k-mooney: IIRC I validate the checksum for the read-only portion there
15:03:49 sean-k-mooney oh in the nova code?
15:03:57 sean-k-mooney i dont think i recall seeing that
15:04:06 dmitriis sean-k-mooney: no-no, in the Libvirt code that parses VPD
15:04:12 sean-k-mooney ah
15:04:14 sean-k-mooney ok
15:04:29 dmitriis sean-k-mooney: there is a chance that something may be added to the mellanox CI. I know CX5 hw is there based on the logs but no BF2 (yet)
15:04:47 dmitriis maybe I'll have some info later this week about that
15:05:10 dmitriis there are automation challenges: i.e. we need to bring up devstack + also program the DPU
15:05:19 dmitriis but devices availability first I guess
15:05:26 sean-k-mooney https://github.com/SeanMooney/arbiterd/tree/master/arbiterd_tests/test_data/sys
15:05:26 sean-k-mooney i actully have been doing some experiment on the side lately and as part of my test infra i have a fake copy of part of /sys
15:05:58 sean-k-mooney the idea being that in my func test it would use the fake copy of the file system
15:06:23 sean-k-mooney its too bad we cant create fake pf devices using kernel modules for testing
15:06:50 sean-k-mooney i have looked into it in the past and we can create the fake netdevs for sriov
15:06:52 dmitriis sean-k-mooney: there's netdevsim but it doesn't create PCI devices